ROB-8A
Relay Output Card
Features
- Eight SPDT, Form C Relays (DPDT Optional)
- Fully compatable with any ACCES digital I/O card (except for IOD-64)
- Contacts rated to 2A
- Can mount in ACCES T-BOX
-
As many as four cards (providing 32 relays) can be controlled by a single 24-bit digital I/O port
- Designed, made, supported, and manufactured in the USA
For Remote (RS-485) control of relays, you can also connect the ROB-8A to our RDG-24.
A "Polarity Select" switch on the card provides means to select relay actuation from either high or low logic levels. An LED associated with each relay illuminates when the adjacent relay is energized. Also, Port C (high nibble) bits are coupled to screw terminals on the ROB-8A card for general digital I/O use. The lower nibble Port C bit PC2 is used for read/write select. Lower nibble Port C bits PC1 and PC0 are used for address decoding if more than one ROB-8A card is used on the same I/O port. As many as four ROB-8A's can be connected to one 24-bit I/O port. If only one relay card is used, +5 VDC from the I/O card can power the card. If more than one ROB-8A is to be used, then there is a jumper that should be removed and external +5 VDC can be applied at screw terminals on the card(s).
If your application requires that the relays be in a known state at power-up, you may optionally specify additional 2.2 kilohm pull-up or pull-down resistors on the card. If, for example, you wish all relays to be de-activated at power-up and you will have the polarity switch set for actuation on logic HIGH inputs, then you will want pull-down resistors installed. You may specify this with model number ROB-8A-S04. Conversely, if you intend to set the switch for actuation on logic LOW inputs, then you will want pull-up resistors installed and you may specify this with model number ROB-8A-S03.
Relay outputs are brought out to eight sets of labeled screw terminals. The relays used are UL-recognized, non-latching, polarized units designed to FCC Part 68 isolation requirements. These relays can switch up to two amperes DC current with a resistive load or 1.25 amperes AC. Relays in sockets for easy replacement are available as an extra-cost option, specify model number ROB-8A-S01.
Downloads
Available Reference Manuals
- View / Download the ROB-8A Manual (.PDF)
Available Software Downloads
Drivers and Downloads
Full list of available Downloads: Software Packages, Drivers, Manuals, and other documents
Custom Software
ACCES also offers Custom Software Services for our products. Our prices are unbelievably low, often as inexpensive as free! If you need something tweaked to support your needs, or an entire enterprise application developed from scratch, it is definitely worth your time to inquire with us, first.
Further information about available ACCES Software:
- Redistributing Windows Drivers
- A list of ACCES drivers and the files that compose them under different versions of Windows, so you can easily redistribute ACCES cards and drivers.
Specifications
Relays
- Contacts: Form C, SPDT, non-latching (DPDT optional)
- Contact Material: Gold overlay silver
- Max. Switched Current: 2A DC, 1.25A AC
- Max. Carry Current: 2A, AC or DC
- Max. Switched Voltage: 125 V DC or AC RMS
- Max. Switched Power: 30W (DC), 60VA (AC)
- Operate Time @ nominal voltage: 6 millisecond max (including bounce)
- Release Time @ nominal voltage: 8 milliseconds max (including bounce)
- Mechanical Life Expectancy: 20 million operations min.
Environmental
- Operating temperature Range: 0o to 50oC.
- Storage Temperature Range: -30o to +105oC.
- Humidity: 45 to 85% RH, non-condensing.
Model | Price (USD) |
---|---|
ROB-8A | 125.00 |
Option S01 | 75.00 |
Option S02 | 30.00 |
Option S03 | N/C |
Option S04 | N/C |