ACCES I/O Products supports critical infrastructure as defined by the US Department of Homeland Security and will be open during normal business hours 6 AM to 6 PM to serve our customers.
We are here to support you.

104-AIM-32

Analog Multiplexer

Features

  • Designed to pair with an A/D board to increase channel count and signal conditioning capabilities
  • 32 single-ended or 16 differential inputs
  • 6 software programmable ranges:
      ±25mV, ±50mV, ±0.1V, ±2.5V, ±5V, ±10V
  • Up to 7 104-AIM-32s can be stacked per A/D board for up to 224 S.E. or 112 diff. inputs
  • +5VDC only operation
  • Precision 15VDC sensor excitation
  • 0 to 70°C operating temperature (-40 to +85°C Optional)
  • Input Signal Conditioning Options:
    • 4-20mA inputs
    • RTD measurement
    • Thermocouple measurement
    • Voltage divider on each input
    • RC filters on each input
    • Bridge completion configuration
  • RoHS Available. Please contact us for ordering information
  • Designed, made, supported, and manufactured in the USA
The 104-AIM-32 is an analog signal multiplexer conforming to the PC/104 standard. The card will multiplex and condition 16 differential or 32 single-ended analog signals before passing them to an analog-to-digital converter card like the 104-AIO12-8. A system may comprise one to seven of these cards in tandem with one 104-AIO12-8 A/D converter board. The 104-AIM-32 card may be used as part of a large data acquisition system. The 104-AIM-32A Kit consists of one 104-AIM-32 and one 12-bit 8-input A/D board.

A removable screw-terminal block (Model UTBK-50) is optionally available for the termination of the input signals, which can come from a variety of sources: thermocouples (J,K,T,E,S,R, and B), three-wire RTD’s (both 392-and 385-alpha), strain gages, 4-20mA current inputs as well as DC and AC voltage inputs. Optionally, bridge completion circuit, current to voltage circuit, and current sourcing circuits for the RTD’s may be installed at the factory. A precision 15VDC sensor excitation source is supplied as part of any applicable factory signal conditioning option per channel. To provide reference junction compensation for thermocouple measurements an optional temperature sensor can be installed on the input terminal block. When selected by the multiplexer an input is filtered, amplified, and offset. A convenient feature of this card is that it can be used with mixed-range analog inputs. Each of the 16 differential or 32 single-ended input channels and the 6 voltage ranges for each channel are independentl y software selectable. A mix of differential and single-ended channels as well as different sensor interface configurations for each channel is possible. A major feature of the 104-AIM-32 is automatic offset and gain error correction using digital potentiometers controlled by correction coefficients stored on the card. Calibration software is provided.



Available Reference Manuals

Available Software Downloads

Available Datasheets

Drivers and Downloads

Full list of available Downloads: Software Packages, Drivers, Manuals, and other documents


Custom Software

ACCES also offers Custom Software Services for our products. Our prices are unbelievably low, often as inexpensive as free! If you need something tweaked to support your needs, or an entire enterprise application developed from scratch, it is definitely worth your time to inquire with us, first.

Further information about available ACCES Software:

Redistributing Windows Drivers
A list of ACCES drivers and the files that compose them under different versions of Windows, so you can easily redistribute ACCES cards and drivers.

Specifications


Analog Inputs

  • 32 Single-Ended or 16 Differential inputs
  • Voltage Ranges: ±25mV, ±50mV, ±100mV, ±2.5V, ±5V, ±10V
  • Settling Time: 9µsec to .01% (see online manual for details)
  • Maximum Input Voltage without damage: 250V
  • Input Impedance: 5MΩ Differential, 10MΩ Single Ended
  • Common Mode Voltage: ±15V
  • Temperature Scale Factor: +10mV/°K @ 25°C
  • ESD Protection: up to 2000V
  • Current: 4 to 20mA (factory option)
  • Common Mode Rejection Ratio: Over 100dB
  • Temperature Error @25°C: 1°C typical

Multiplexer Outputs

  • Channels: 1 of 7, jumper selected 8th channel is temp sensor output is used.
  • Output Drive Capability: 600Ω or 10mA
  • Voltage Range: ±10 (x1, x2, x100, x200 gain); ±5 (x0.5, x50)
  • Slew Rate: 2V/µsec

General

  • Power Required: +5V @ 200mA with with no load for excitation
  • Interrupt Requests: none
  • Gain Nonlinearity: ±0.005%
  • Humidity Tolerance: 5 to 95% RH non-condensing
  • Operating Temperature: 0 to 70°C, (-40 to 85°C Optional)
  • Storage Temperature: -55 to +125°C
  • Temperature Coefficient of Gain: Removed by Gain Calibration

CE testing & approval must be done at the system level, in the designed enclosure, and is not done on individual boards.


 
ModelPrice (USD)
104-AIM-32310.00
104-AIM-32A Kit395.00

Acquisition, Control, Communication: Engineering and Systems